Backflow Preventer Jacksonville Irrigation
Backflow Preventer Jacksonville Irrigation
If you have an irrigation system in Jacksonville, you have (or need) a backflow preventer. It's that brass assembly sticking up somewhere in your yard, often near the water meter or on the side of your house. Most homeowners ignore it until it leaks, freezes, or fails an inspection.
Backflow preventers protect your drinking water from contamination. Without one, irrigation water—which has been sitting in pipes, mixed with fertilizer or pesticides, or drawn from questionable sources—can flow backward into your household plumbing. That's a serious health hazard and a code violation in Jacksonville.
I've replaced dozens of backflow preventers damaged by freezes, poor installation, or lack of maintenance. These devices are required by Jacksonville code and JEA, and they need proper installation, annual testing, and basic winterization. Here's what every Jacksonville homeowner needs to know.
What Backflow Preventers Do
Your irrigation system operates at lower pressure than your household water supply most of the time. But various situations can create reverse pressure:
- Backsiphonage: Sudden pressure drop in the main water line (from firefighting, main break, or high demand) creates suction that pulls irrigation water backward into household supply
- Backpressure: Irrigation pump pressure exceeds supply pressure, forcing water backward
- System shutdown: When system shuts off, residual pressure can force water backward
A backflow preventer contains check valves that allow water to flow only in one direction—from the potable supply to your irrigation system. If pressure reverses, the valves close and prevent contaminated water from entering your drinking water.
Types of Backflow Preventers
Several types exist, each suited for different situations and offering different levels of protection.
Atmospheric Vacuum Breaker (AVB)
The simplest and cheapest type. Consists of a check valve and an air inlet that opens when pressure drops, breaking the vacuum.
Where used: Hose bibs, drip irrigation connections, small residential systems.
Pros: Inexpensive ($15-40), easy to install, no testing requirement in most cases.
Cons: Must be installed at least 6 inches higher than the highest downstream point, can't have shutoff valve downstream, can't handle continuous pressure. Not suitable for most permanent irrigation systems.
Jacksonville application: Rarely adequate for full irrigation systems. Sometimes used for garden hose connections or small drip systems.
Pressure Vacuum Breaker (PVB)
Step up from AVB. Contains two check valves and an air inlet. Must be installed above all downstream components.
Where used: Common for residential irrigation systems in Jacksonville.
Pros: Relatively inexpensive ($80-200), effective protection, widely available.
Cons: Must be installed 12 inches above highest sprinkler head or emitter, not for use with booster pumps or well systems, requires annual testing, vulnerable to freezing.
Jacksonville application: Most common type for standard residential irrigation systems connected to JEA water supply.
Reduced Pressure Zone (RPZ) Assembly
Highest level of protection. Contains two check valves with a pressure-monitored chamber between them. If either valve fails, water discharges through a relief valve.
Where used: Commercial properties, high-hazard situations, well water systems, properties with chemical injection.
Pros: Highest protection level, can be installed below grade in a vault, works with pumps and booster systems.
Cons: Expensive ($300-800+), requires annual testing by certified tester, more complex installation, can discharge water periodically (by design).
Jacksonville application: Required for commercial irrigation, irrigation systems using well water, any system with chemical injection (fertilizer, pesticides), and increasingly required for new residential construction.
Double Check Valve (DCV)
Contains two check valves in series. Simpler than RPZ but less protection.
Where used: Low-hazard situations, fire sprinkler connections.
Pros: Less expensive than RPZ, can be installed below grade.
Cons: Lower protection level, requires annual testing, not approved for all situations.
Jacksonville application: Rarely used for irrigation; mostly fire protection systems.
Jacksonville Code Requirements
Jacksonville follows Florida Building Code and Jacksonville Municipal Code for backflow prevention. Key requirements:
Installation Requirements
- All permanent irrigation systems must have backflow prevention (City of Jacksonville Ordinance)
- Type depends on hazard level and installation specifics
- Must be installed by licensed plumber (for connection to potable water supply)
- Must be tested annually by certified backflow prevention tester
- JEA must be notified of backflow preventer installation
PVB-Specific Requirements
- Install at least 12 inches above highest downstream point
- Install outside, exposed to atmosphere
- Install on vertical supply line
- No shutoff valves downstream of device
- Must have proper clearance for testing and maintenance
RPZ-Specific Requirements
- Can be installed in-ground in approved vault with drainage
- Must have minimum 12-inch clearance above floor for testing
- Vault must be large enough for tester access
- Drainage must be provided for relief valve discharge
- Can be installed indoors if proper drainage provided
Testing Requirements
- Annual testing required for PVB and RPZ assemblies
- Must be tested by certified tester (passing Florida Backflow Prevention Certification exam)
- Test results must be submitted to JEA within 30 days of test
- Failure to test can result in water shut-off
JEA maintains a list of certified testers and sends annual reminders to properties with registered backflow preventers.
Installation Considerations for Jacksonville
Our climate and soil create specific challenges for backflow preventer installation.
Location Selection
Ideal location:
- Close to water meter or main supply line
- Accessible for testing and maintenance
- Protected from lawn equipment and foot traffic
- Visible enough to monitor for leaks
- 12+ inches above highest sprinkler (for PVB)
Common Jacksonville locations:
- Side of house near water meter
- Front corner of property near street
- Inside fence near gate
- On standalone post in landscaping
Avoid placing directly in mowed areas—get hit by a mower enough times and you'll crack the brass housing.
Height Requirements
For PVB assemblies, the air inlet must be 12 inches above the highest downstream point. In Jacksonville's mostly flat terrain, this usually isn't difficult. But if you have:
- Hillside properties near the river or on elevated areas
- Second-story irrigation for balcony containers
- Slope that raises rear yard significantly
You may need to install very high, use an RPZ instead, or redesign system layout.
Drainage Considerations
PVBs discharge water during normal operation—this is by design. The area below needs adequate drainage. Sandy Jacksonville soil usually drains well, but in areas with:
- High water table (near St. Johns River, Intracoastal, retention ponds)
- Clay pockets
- Compacted soil
You may need to install a small French drain or drainage rock around the backflow preventer.
RPZ assemblies discharge more water during testing and if valves fail. Plan for this with drainage to a non-erosive area.
Freeze Protection
Jacksonville's occasional hard freezes are the number one cause of backflow preventer damage. The brass housing and internal components can crack if water freezes inside.
Installation considerations:
- South-facing location warms faster in sun
- Protected from north wind (behind wall, fence, vegetation)
- Easy to wrap with insulation for freeze events
See the Sprinkler System Winterization article for detailed freeze protection procedures.
Accessibility
Testers need access to four test cocks (small valves) on the device. Ensure:
- Adequate clearance on all sides (minimum 6 inches)
- No landscape fabric, plants, or mulch blocking test cocks
- Stable standing area for tester
- Clear path to backflow preventer
I've seen systems where homeowners landscaped around the backflow preventer, covering test cocks with mulch or planting shrubs tight against it. This makes testing difficult or impossible.
Installation Process
This is overview only—actual installation should be done by a licensed plumber for code compliance and proper water connection.
Step 1: Plan Location
Considering factors above, mark proposed location. Verify it meets height requirements and has adequate drainage.
Step 2: Install Support
PVB assemblies mount on a vertical riser. Install:
- PVC riser from supply line (sized to match assembly—usually 3/4" or 1")
- Riser should extend above ground level by the amount needed to meet height requirements
- Use proper PVC cement and allow to cure
- Some installers use galvanized pipe for above-ground portion (more durable against impacts)
For RPZ in vault:
- Excavate vault location
- Install precast vault or build to code specifications
- Ensure adequate size and drainage
Step 3: Mount Assembly
Attach backflow preventer to riser:
- Use proper thread sealant rated for potable water
- Orient assembly according to flow direction (marked with arrow)
- Ensure air inlet faces up and is unobstructed
- Tighten connections properly (don't overtighten brass—it can crack)
Step 4: Connect Downstream Piping
Run pipe from backflow preventer outlet to irrigation system:
- Use schedule 40 PVC rated for irrigation
- Transition underground at least 12 inches from device
- Slope away from device for drainage
- No shutoff valves between backflow preventer and first irrigation zone (code violation)
Step 5: Pressure Test
Before covering or connecting to irrigation system:
- Turn on water supply
- Check all connections for leaks
- Verify proper operation
- Let run for 10-15 minutes and recheck
Step 6: Initial Testing
Once installation is complete, have a certified tester perform the initial test:
- Verifies device functions correctly
- Documents installation
- Registers device with JEA
- Provides baseline for future testing
Step 7: Protect and Mark
- Install bollards or landscape design to protect from impacts
- Mark location clearly (some use decorative stones, plant markers, etc.)
- Document location in home records
- Schedule annual testing reminder
Annual Testing Process
Florida law requires annual testing of PVB and RPZ assemblies by certified testers.
What Testing Involves
Tester will:
- Verify assembly information (model, serial number, size)
- Attach test kit (specialized gauge assembly)
- Test check valve #1 (must hold pressure)
- Test check valve #2 (must hold pressure)
- Test air inlet (must open at correct differential pressure)
- Test relief valve (for RPZ—must open at correct differential pressure)
- Document results
Testing takes 15-30 minutes. Be prepared for water to discharge during testing—this is normal.
Test Results
Pass: Device meets specifications, safe for another year. Tester submits results to JEA.
Fail: Device doesn't meet specifications, needs repair or replacement. You have limited time to fix and retest before JEA takes action.
Common failure reasons:
- Check valves worn or fouled with debris
- Springs weakened
- Seals degraded
- Freeze damage
- Mineral buildup
Cost
Testing costs $50-100 per device typically. Some irrigation companies include this in maintenance packages.
Scheduling
JEA sends annual reminders to registered addresses. Schedule testing during mild weather (March-May or October-November in Jacksonville) to avoid both freeze risk and peak summer heat.
Many homeowners coordinate backflow testing with irrigation system start-up or seasonal check.
Maintenance and Troubleshooting
Backflow preventers need minimal maintenance but attention to a few things extends life.
Regular Inspection
Monthly quick checks:
- Visual inspection for leaks
- Check for corrosion or damage
- Verify area drains properly
- Ensure no obstructions around device
Cleaning
Annually (before testing):
- Wipe down exterior
- Clear debris from air inlet
- Remove grass clippings or mulch
- Ensure test cocks are accessible
Common Problems
Water dripping from air inlet: Normal during and briefly after irrigation cycles. Persistent dripping indicates check valve issue—schedule testing.
Constant water discharge: Indicates check valve or relief valve failure. Shut off system and call for service.
Leaking connections: Usually from freeze damage or loose fittings. Tighten or replace as needed.
Reduced water pressure: Can indicate partially closed check valves or debris. May need disassembly and cleaning.
Corrosion: Brass corrosion (green/white buildup) is common in Jacksonville's humid climate. Light corrosion is cosmetic, but heavy corrosion can affect function. Monitor and replace if function is impaired.
Winterization
Before forecast freezes:
- Insulate thoroughly with foam covers, towels, or commercial insulation
- Wrap with plastic to protect insulation from rain
- For extreme cold (below 25°F), consider draining by opening test cocks
- Remove insulation after freeze passes to prevent moisture buildup
See the Sprinkler System Winterization article for detailed procedures.
Repair vs. Replacement
Failed backflow preventers can sometimes be repaired, sometimes need replacement.
Repairable Situations
- Check valve seats and springs worn (rebuild kits available)
- O-rings and seals degraded (replacement parts available)
- Minor freeze damage (sometimes, if housing isn't cracked)
- Test cocks damaged (replaceable)
Replacement Necessary
- Cracked housing (common from freeze or impact)
- Major corrosion affecting structural integrity
- Obsolete models without available parts
- Repeated failures after repair
Cost comparison:
- Rebuild kit: $30-60
- Labor for rebuild: $75-150
- New PVB assembly: $80-200
- New RPZ assembly: $300-800
- Labor for replacement: $150-300
Sometimes replacement makes more economic sense than repair, especially for older units.
Choosing a Backflow Tester
JEA maintains a list of certified testers, but quality varies. Look for:
- Current Florida certification (verify with state database)
- Registered with JEA
- Calibrated test equipment (should be re-calibrated annually)
- Professional documentation practices
- Reasonable pricing ($50-100 is typical)
- Willing to explain results and recommend repairs if needed
Many irrigation companies employ certified testers and offer testing as part of service packages.
New Construction and System Upgrades
If you're installing a new irrigation system or upgrading an existing one:
Select Appropriate Type
- Standard residential: PVB usually adequate and more cost-effective
- Well water: RPZ required
- Chemical injection: RPZ required
- Booster pump: RPZ required
- Commercial property: RPZ usually required
Work with Licensed Professionals
- Licensed plumber for backflow preventer installation
- Licensed irrigation contractor for system design and installation
- Certified tester for initial test and registration
Don't cut corners here—improper installation leads to code violations, failed inspections, and potential water shut-off.
Register with JEA
Ensure your installer registers the backflow preventer with JEA. This ensures you receive annual testing reminders and are in compliance.
Code Enforcement and Penalties
Jacksonville and JEA take backflow prevention seriously. Consequences of non-compliance:
- Warning letter for missed testing
- Water shut-off for persistent non-compliance
- Fines for code violations
- Liability if contamination event occurs
The annual test requirement isn't optional. Budget for it as part of irrigation system ownership.
The Bottom Line
Backflow preventers are required, must be properly installed and tested annually, and need basic protection from Jacksonville's occasional freezes. They're not exciting, but they're essential for protecting water quality and complying with code.
If you have an irrigation system and don't know where your backflow preventer is or when it was last tested, that's your first action item. Locate it, inspect it, and schedule testing if you're overdue.
For new installations, work with licensed professionals and ensure proper registration. For existing systems, annual testing and basic winterization prevent most problems. The investment is minimal compared to the importance of protecting your drinking water and avoiding code violations.
Jacksonville's water supply is excellent—let's keep it that way by maintaining proper backflow prevention on irrigation systems.
Need Professional Sod Installation?
Jax Sod connects you with expert installers across Jacksonville and Northeast Florida. Over 40 Years of experience. Free quotes!
Related Articles

Drip Irrigation for Gardens Jacksonville
Complete guide to drip irrigation systems for Jacksonville gardens. Design tips, installation steps, and maintenance for Zone 9a/9b vegetable and flower gardens.

Smart Irrigation Systems for Jacksonville Lawns
Smart irrigation systems Jacksonville homeowners trust for water savings, SJRWMD compliance, and healthier lawns in Florida's sandy soil.

The Golden Rules of Irrigation in Northeast Florida
Stop guessing with your sprinkler timer. Learn the science of deep watering to promote drought-tolerant roots and avoid fungus in St. Augustine and Zoysia lawns.
Ready to Transform Your Lawn?
Get a free, no-obligation quote from Jacksonville's trusted sod experts. With over 40 years of experience, we'll connect you with the right installers for a perfect lawn.